System Control Solutions Ltd
.

System Control Solutions Ltd

7 Barley Way
South Lowestoft Industrial Estate
Lowestoft, Suffolk. NR33 7NH

Fade_Bar1.gif (2605 bytes)

Moeller Soft Starter DS4 Range

[picture of DS4 Soft Starter]

Controlled switching and starting

Features

  • Simple handling.
  • Terminals similar to contactor.
  • Mounting on top hat or DIN rails or fixing with screws.
  • Can be grouped side-by-side.
  • Degree of protection IP 20.
  • Heat sink integrated into enclosure.
  • Selective multi-voltage input for the control voltage.
  • Status indication via LED.
  • CE conformity.
  • UL approval (File No. E236856).

 

Application Examples

  • Three-phase resistive and inductive loads.
  • Soft switching of motor starters in transport and conveyor belts.
  • High switching cycles of motors in packaging machines.
  • Silent switching of light and heating in buildings.
  • Soft starting of pumps reduces the load on the entire installation (water impact).
  • Solid-state switching of pumps in the extreme environments of chemical plants and filling stations.
  • Fast and silent control in the buildings field with reversing function with lift doors, garage gates and conveyor belts in the cooling and checkout area.
  • Smooth start that reduces wear on V-belts in fan drives.

Power supply
110–500 V ±10 %, 50/60 Hz

Control voltage
15–30 VDC / 110–240 VAC

Performance range
6–23 A (AC53, inductive load)
2.2–11 kW (motors)
7.5–15 kW (with internal bypass)
18.5–22 kW (with external bypass)
 

Performance characteristic
DS4-340-...-M(R)
AC53b, 600 starts per hour with 6-times starting current for 0.5 seconds
AC53b, 20 starts per hour with 6-times starting current for 5 seconds
DS4-340-...-MX(R)
AC53a, 10 starts per hour with 3-times starting current for 5 seconds

The two-phase controlled compact starter DS4 in various versions for standard applications up to 15 kW

DS4-340-...-M





  DS4-340-...-MR





DOL starter 2.2 to 11 kW   Reversing starter 2.2 to 11 kW
 
DS4-340-...-MX



  DS4-340-...-MXR



Motor starter with internal bypass contacts 7.5 to 15 kW 6–23 A (AC53, inductive load)   Reversing starter with internal bypass contacts 7.5 to 15 kW

 

  DOL-start, without delay (tSTART)

  Operation with acceleration and delay time (tSTART, tSTOP)

  Operation with direction of rotation

  Reversing starter, two directions of rotation

 

DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTADVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS,DVP-EX, PLCs, DELTA ELECTRONICS, SYSTEM CONTROL SOLUTIONS ELECTRONICS, SYSTEM CONTROL SOLUTIONS,

 

SCS Brochure AdobeIcon.gif (134 bytes) Adobe PDF File

Return to Home Page