The
Vacon
NXS
is
a
compact
AC
drive
in
the
power
range
of
0.37-560
kW
and
supply
voltages
of
208-690
V
for
heavy
use
in
machines,
buildings
and
all
branches
of
industry.
The
robust
design
incorporates
effective
protection
against
supply
network
disturbances.
Trip-free
operation
is
also
guaranteed
due
to
sophisticated
motor
control
principles
and
motor/drive
protection
features,
component
selection
and
effective
cooling.
Enclosure
classes
of
IP21
and
IP54
and
integrated
high-level
EMC
filters
make
the
Vacon
NXS
suitable
for
all
environments.
The
Start-Up
Wizard
and
the
standard
All-In-One
Application
Package
make
parameter
setting
extremely
easy
in
all
cases,
from
simple
to
complex.
The
wide
and flexible
standard
I/O
and
option
for
five
I/O
boards
provide
versatile
controllability.
The
most
common
fieldbus
options
are
also
available.
The
modular
design
of
the
Vacon
NXS
brings
several
advantages:
the
control
terminals
are
safely
separated
from
power
terminals,
upgrading
the
control
inputs
and
outputs
is
easy
and
convenient,
replacing
the
cooling
fan
(the
only
regularly
replaceable
component)
is
fast,
the
display
panel
can
be
utilized
for
parameter
copying,
etc.
- Easy to use display panel
- Start-Up Wizard
- All-in-One Application Package
- Versatile PID controller and pump automatic for 1-5 pumps
- Special applications available (water control, high speed, etc.)
- Five slots for control boards (2 basic boards and 3 option boards)
- High switching frequency, low noise
- Steady state speed error < 1%
- Low torque ripple
- Starting torque > 200%, depending on AC drive sizing
- Suitable for multi-motor applications
The
mechanical
design
is
extremely
compact.
The
IP54
units
in
particular
are
the
smallest
AC
drives
on
the
market.
All
units
are
suitable
for
both
wall
and
enclosure
mounting
with
all
necessary
components:
integrated
EMC
filters,
AC
chokes,
cable
protection,
dust
and
water
protection.
The
effective
super-cooling
principle
allows
high
ambient
temperatures
and
high
switching
frequencies
without
de-rating.
There
are
no
fixed
inputs
or
outputs
in
the
Vacon
NXS.
There
are
five
slots
(A,
B,
C,
D
and
E)
for
I/O
boards,
and
a
suitable
board
can
be
selected
for
each
slot.
The
NXS
units
are
delivered
with
OPT-A1
and
OPT-A2
boards
if
the
I/O
is
not
specified.
In
many
countries,
boards
OPT-A1
and
OPT-A3
are
used
as
standard
I/O
as
the
galvanically
(double)
isolated
thermistor
input
is
often
required.
Removable
terminals,
snap-in
card
installation,
automatic
card
identification
and
instructions
on
the
drive
help
making
quick
connections.
If
necessary,
the
inputs,
outputs
and
fieldbus
boards
can
be
added
in
the
field.
The
Vacon
NXS
is
simply
the
most
flexible
frequency
converter
series
on
the
market.
An
external
+24
V
supply
option
enables
communication
with
the
control
unit
even
if
the
mains
supply
is
switched
off
(e.g.
fieldbus
communication
and
parameter
settings).
The
uncluttered
text
display
panel
with
a
well-defined
menu
structure
and
functions
such
as
parameter
copy
and
start-up
wizard
makes
commissioning
and
fine-tuning
as
easy
as
possible.

A
maximum
of
three
values
can
be
monitored
simultaneously
(the
multi-monitoring
feature).
The
All-in-One
application
package
has
seven
applications
(=default
settings
and
functionality
of
control
inputs
and
outputs)
which
can
be
selected
with
one
parameter.
The
application
will
also
be
requested
by
the
Start-up
Wizard
at
the
first
power-up.
With
this
single
setting,
the
controls
can
be
programmed
e.g.
for
two
external
control
places
or
a
pressure
control
with
the
integrated
PID
controller.
In
most
cases,
the
default
basic
application
is
suitable
and
only
the
min/max
frequencies
as
well
as
motor
nominal
values
must
be
set.
Thanks
to
the
modular
software
applications
made
by
the
Vacon
NC1131-3
Engineering
tool,
the
All-in-One
application
package
can
be
replaced
by
the
Water
application
package
that
contains
several
pre
configured
applications
optimized
for
water
handling.
There
are
also
several
other
general-purpose
software
applications
available.